Zemāk ir dump no Xyratex SES atbilstīgu kamerā, izmantojot SANtools smartmon-UX programmatūru . To daļu zilā krāsā ir pārdevējs specifiskas.

 Configuration switches numbered from 1-12 as viewed from rear, top to bottom Vendor-specific features (Notes) [SWITCH SETTING] SoftSelect Mode             (Disabled) [SW11-OFF] Drive Speed                 (2 Gbit FC Mode) root @ morph smartmon] #. / smartmon-UX-E + / dev / SDC SMARTMon-UX [Release 1,23, Build 30-Nov-2003] - Autortiesības 2003 SANtools, Inc http://www.SANtools.com SEAGATE ST336753FC S / N "3HX00LE3" uz / dev / SDC [SES] (Nav pilnvarojuma SMART) (35003 MB) Atklājējs XYRATEX RS1600-FC2-FFX2 WWN = 20-00-00-50-CC-00-7B-8E: konfigurācija slēdži numurēta 1-12, kā skatoties no aizmugures, augšas uz leju Pārdevējs-īpatnības (Piezīmes) [SWITCH SETTING] SoftSelect Mode (Disabled) [SW11-OFF] Drive Speed (2 Gbit FC režīms)   [Row=1 Col=1] Device #1 Not Installed SelID=05h [Row=1 Col=2] Device #2 OK SelID=06h [Row=1 Col=3] Device #3 Not Installed SelID=07h [Row=1 Col=4] Device #4 Not Installed SelID=08h [Row=2 Col=1] Device #5 Not Installed SelID=09h [Row=2 Col=2] Device #6 Not Installed SelID=0ah [Row=2 Col=3] Device #7 Not Installed SelID=0bh [Row=2 Col=4] Device #8 Not Installed SelID=0ch [Row=3 Col=1] Device #9 Not Installed SelID=0dh [Row=3 Col=2] Device #10 Not Installed SelID=0eh [Row=3 Col=3] Device #11 Not Installed SelID=0fh [Row=3 Col=4] Device #12 OK SelID=10h [Row=4 Col=1] Device #13 Not Installed SelID=11h [Row=4 Col=2] Device #14 OK SelID=12h [Row=4 Col=3] Device #15 OK SelID=13h [Row=4 Col=4] Power Supply #0 Critical DC Undervoltage AC failure DC failure [LED ON] Power Supply #1 OK Cooling Element #0 OK fan at speed 4 Cooling Element #1 OK fan at speed 4 Temperature Sensor #0 OK 104F/40C Audible Alarm #0 OK ENABLED sounding CRITICAL SESElectronics Processor #0 OK [ACTIVE] SESElectronics Processor #1 OK [PASSIVE] Cilpa Config (1 x 16 cilpas) [SW1-ON] Rumbas Mode (Pielikums ar rumbas režīmā) [SW3-ON] Rezervēts (rezervēts) [SW4-OFF] SES ziņojums (Ziņojums Bita vienīgajā) Power atlaistajām norādi (Pielikums norāda atlaišana) Ops Panel zems Mode (Enclosure, kas atgādinātu režīmā) Drive risināšana Mode: 0 (1 x 16 JBOD) Vienības Izvēlēties Switch: 1 Modelis ir: Goshawk - Mylex FFX2 RAID 2Gbit divu portu kontrolieri maģistra LRC Firmware līmenis: 35 SFP Host 0 Present (LoopA): JĀ SFP Host 0 Labas (A): NO SFP Host 1 Present (): JĀ SFP Host 1 Good (A): NO SFP Expansion Present (): NO SFP Expansion Good (A): NO SFP Host 0 Present (LoopB): JĀ SFP Host 0 Labas (B): NO SFP Host 1 Present (B): NO SFP Host 1 Good (B): NO SFP Expansion Present (B): JĀ SFP Expansion Good (B): NĒ ierīce # 0 OK SelID = 04h [rinda = 1 Col = 1] Device # 1 nav instalēts SelID = 05h [rinda = 1 Col = 2] Ierīce # 2 Labi SelID = 06h [rinda = 1 Col = 3] Device # 3 Ne uzstādītas SelID = 07h [rinda = 1 Col = 4] Device # 4 nav instalēts SelID = 08h [Row = 2 Pulkvedis = 1] Device # 5 Ne Installed SelID = 09h [Row = 2 Pulkvedis = 2] Ierīce # 6 nav instalēti SelID = 0ah [Row = 2 Pulkvedis = 3] Device # 7 nav instalēts SelID = 0bh [Row = 2 Pulkvedis = 4] Device # 8 nav instalēts SelID = 0ch [Rindu = 3 Pulkvedis = 1] Device # 9 nav instalēts SelID = 0dh [Rindu = 3 Pulkvedis = 2] Ierīce # 10 nav instalēts SelID = 0eh [Rindu = 3 Pulkvedis = 3] Device # 11 nav instalēts SelID = 0fh [Rindu = 3 Pulkvedis = 4] Device # 12 Labi SelID = 10s [Row = 4 Col = 1] Device # 13 nav instalēts SelID = 11H [Rindu = 4 Col = 2] Ierīce # 14 Labi SelID = 12h [Rindu = 4 Col = 3] Device # 15 Labi SelID = 13s [Rindu = 4 Col = 4 ] Power Supply # 0 kritisko DC Undervoltage AC mazspēja DC mazspēju [LED ON] Barošanas # 1 OK Dzesēšanas Element # 0 OK ventilatora ātrumā 4 Dzesēšanas Element # 1 OK ventilatora ātrumā 4 temperatūras sensoru # 0 OK 104F/40C skaņas signāls # 0 OK Enabled skan KRITISKO SESElectronics Procesors # 0 OK [ACTIVE] SESElectronics Procesors # 1 OK [PASĪVIE]    Slieksnis Informācija Brīdinājums Range kritisko Range Temperatūras sensors # 0: 30-74 20-78   Modulis Vietas - Front View Col-1 Col-2 Col-3 Col-4 +-------------------------------- ------+ | Dev # 00 | Dev # 01 | Dev # 02 | Dev # 03 | Rinda-1 | Dev # 04 | Dev # 05 | Dev # 06 | Dev # 07 | Row-2 | Dev # 08 | Dev # 09 | Dev # 10 | Dev # 11 | Rinda-3 | Dev # 12 | Dev # 13 | Dev # 14 | Dev # 15 | Rinda-4 +------------ --------------------------+    Modulis Vietas - Aizmugures Apskatīt +--------------------------------------+ | PSU / | 2. | 1 | OPS | PSU / | | Dzesēšanas | LRC | LRC | Panel | Dzesēšanas | | First | 'B' | '' | | otrais | | # 0 | # 1 | # 0 | | 1 | # <- SES ID # +--------------------------------------+    Apzīmējumi uz Tālāk: SN = Serial # (pēc izvēles) SC = Statusa kods LRC-: SN = PMT317000005619 LRC-B: SN = PMT317000005396 Barošanas # 1: SN = IMS4204300008BB Enerģijas avots # 2: SN = IMS4204300007F7    Programmas izpildi. 

,

  1. Tādi komentāri yet.
  1. Nr trackbacks vēl.
Tev jābūt iegājušam, lai ievietotu komentārus.
Theme Tweaker ar Unreal