Home > Enclosure Management, SES > Example SES (SCSI Enclosure Services) Reports

Example SES (SCSI Enclosure Services) Reports

January 2nd, 2009 Leave a comment Go to comments

Below is a  dump from a Xyratex SES compliant enclosure, using SANtools smartmon-ux software.  Portions in blue are vendor-specific.

root@morph smartmon]# ./smartmon-ux -E+ /dev/sdc
SMARTMon-ux [Release 1.23, Build 30-NOV-2003] - Copyright 2003 SANtools, Inc. http://www.SANtools.com SEAGATE ST336753FC S/N "3HX00LE3" on /dev/sdc [SES] (Not Enabling SMART)(35003 MB)
Discovered XYRATEX  RS1600-FC2-FFX2  WWN=20-00-00-50-CC-00-7B-8E:
Configuration switches numbered from 1-12 as viewed from rear, top to bottom
Vendor-specific features (Notes) [SWITCH SETTING]
SoftSelect Mode             (Disabled) [SW11-OFF]
Drive Speed                 (2 Gbit FC Mode)
Loop Config                 (1 x 16 loop) [SW1-ON]
Hub Mode                    (Enclosure in hub mode) [SW3-ON]
Reserved                    (reserved) [SW4-OFF]
SES Report                  (REPORT bit set on single)
Power Redundancy Indication (Enclosure indicates redundancy)
Ops Panel Muted Mode        (Enclosure in REMIND mode)
Drive Addressing Mode:      0 (1 x 16 JBOD)
Unit Select Switch:         1
Model is: Goshawk - Mylex FFX2 RAID 2Gbit dual port controller
Master LRC Firmware level:  35
SFP Host 0 Present (LoopA): YES
SFP Host 0 Good (A):        NO
SFP Host 1 Present (A):     YES
SFP Host 1 Good (A):        NO
SFP Expansion Present (A):  NO
SFP Expansion Good (A):     NO
SFP Host 0 Present (LoopB): YES
SFP Host 0 Good (B):        NO
SFP Host 1 Present (B):     NO
SFP Host 1 Good (B):        NO
SFP Expansion Present (B):  YES
SFP Expansion Good (B):     NO
Device #0 OK SelID=04h [Row=1 Col=1]
Device #1 Not Installed SelID=05h [Row=1 Col=2]
Device #2 OK SelID=06h [Row=1 Col=3]
Device #3 Not Installed SelID=07h [Row=1 Col=4]
Device #4 Not Installed SelID=08h [Row=2 Col=1]
Device #5 Not Installed SelID=09h [Row=2 Col=2]
Device #6 Not Installed SelID=0ah [Row=2 Col=3]
Device #7 Not Installed SelID=0bh [Row=2 Col=4]
Device #8 Not Installed SelID=0ch [Row=3 Col=1]
Device #9 Not Installed SelID=0dh [Row=3 Col=2]
Device #10 Not Installed SelID=0eh [Row=3 Col=3]
Device #11 Not Installed SelID=0fh [Row=3 Col=4]
Device #12 OK SelID=10h [Row=4 Col=1]
Device #13 Not Installed SelID=11h [Row=4 Col=2]
Device #14 OK SelID=12h [Row=4 Col=3]
Device #15 OK SelID=13h [Row=4 Col=4]
Power Supply #0 Critical DC Undervoltage AC failure DC failure [LED ON]
Power Supply #1 OK
Cooling Element #0 OK fan at speed 4
Cooling Element #1 OK fan at speed 4
Temperature Sensor #0 OK 104F/40C
Audible Alarm #0 OK ENABLED sounding CRITICAL
SESElectronics Processor #0 OK [ACTIVE]
SESElectronics Processor #1 OK [PASSIVE]
 
Threshold Information                   Warning Range   Critical Range
Temperature Sensor #0:                    30 - 74          20 - 78
 
Module Locations - Front View
 Col-1     Col-2     Col-3     Col-4
+--------------------------------------+
|Dev #00 | Dev #01 | Dev #02 | Dev #03 | Row-1
|Dev #04 | Dev #05 | Dev #06 | Dev #07 | Row-2
|Dev #08 | Dev #09 | Dev #10 | Dev #11 | Row-3
|Dev #12 | Dev #13 | Dev #14 | Dev #15 | Row-4
+--------------------------------------+
 
Module Locations - Rear View
+--------------------------------------+
| PSU /    | 2nd | 1st |OPS  | PSU /   |
| Cooling  | LRC | LRC |Panel| Cooling |
| First    | 'B' | 'A' |     | Second  |
|   #0     | #1  | #0  |     |  #1     | <--SES ID#
+--------------------------------------+
 
Legend for Below: SN=Serial#, (optional)SC=Status Code
 LRC-A: SN=PMT317000005619
 LRC-B: SN=PMT317000005396
 Power Supply#1: SN=IMS4204300008BB
 Power Supply#2: SN=IMS4204300007F7
 
Program Ended.