Example SES (SCSI Enclosure Services) Reports
January 2nd, 2009
Below is a dump from a Xyratex SES compliant enclosure, using SANtools smartmon-ux software. Portions in blue are vendor-specific.
root@morph smartmon]# ./smartmon-ux -E+ /dev/sdc SMARTMon-ux [Release 1.23, Build 30-NOV-2003] - Copyright 2003 SANtools, Inc. http://www.SANtools.com SEAGATE ST336753FC S/N "3HX00LE3" on /dev/sdc [SES] (Not Enabling SMART)(35003 MB) Discovered XYRATEX RS1600-FC2-FFX2 WWN=20-00-00-50-CC-00-7B-8E: Configuration switches numbered from 1-12 as viewed from rear, top to bottom Vendor-specific features (Notes) [SWITCH SETTING] SoftSelect Mode (Disabled) [SW11-OFF] Drive Speed (2 Gbit FC Mode) Loop Config (1 x 16 loop) [SW1-ON] Hub Mode (Enclosure in hub mode) [SW3-ON] Reserved (reserved) [SW4-OFF] SES Report (REPORT bit set on single) Power Redundancy Indication (Enclosure indicates redundancy) Ops Panel Muted Mode (Enclosure in REMIND mode) Drive Addressing Mode: 0 (1 x 16 JBOD) Unit Select Switch: 1 Model is: Goshawk - Mylex FFX2 RAID 2Gbit dual port controller Master LRC Firmware level: 35 SFP Host 0 Present (LoopA): YES SFP Host 0 Good (A): NO SFP Host 1 Present (A): YES SFP Host 1 Good (A): NO SFP Expansion Present (A): NO SFP Expansion Good (A): NO SFP Host 0 Present (LoopB): YES SFP Host 0 Good (B): NO SFP Host 1 Present (B): NO SFP Host 1 Good (B): NO SFP Expansion Present (B): YES SFP Expansion Good (B): NO Device #0 OK SelID=04h [Row=1 Col=1] Device #1 Not Installed SelID=05h [Row=1 Col=2] Device #2 OK SelID=06h [Row=1 Col=3] Device #3 Not Installed SelID=07h [Row=1 Col=4] Device #4 Not Installed SelID=08h [Row=2 Col=1] Device #5 Not Installed SelID=09h [Row=2 Col=2] Device #6 Not Installed SelID=0ah [Row=2 Col=3] Device #7 Not Installed SelID=0bh [Row=2 Col=4] Device #8 Not Installed SelID=0ch [Row=3 Col=1] Device #9 Not Installed SelID=0dh [Row=3 Col=2] Device #10 Not Installed SelID=0eh [Row=3 Col=3] Device #11 Not Installed SelID=0fh [Row=3 Col=4] Device #12 OK SelID=10h [Row=4 Col=1] Device #13 Not Installed SelID=11h [Row=4 Col=2] Device #14 OK SelID=12h [Row=4 Col=3] Device #15 OK SelID=13h [Row=4 Col=4] Power Supply #0 Critical DC Undervoltage AC failure DC failure [LED ON] Power Supply #1 OK Cooling Element #0 OK fan at speed 4 Cooling Element #1 OK fan at speed 4 Temperature Sensor #0 OK 104F/40C Audible Alarm #0 OK ENABLED sounding CRITICAL SESElectronics Processor #0 OK [ACTIVE] SESElectronics Processor #1 OK [PASSIVE] Threshold Information Warning Range Critical Range Temperature Sensor #0: 30 - 74 20 - 78 Module Locations - Front View Col-1 Col-2 Col-3 Col-4 +--------------------------------------+ |Dev #00 | Dev #01 | Dev #02 | Dev #03 | Row-1 |Dev #04 | Dev #05 | Dev #06 | Dev #07 | Row-2 |Dev #08 | Dev #09 | Dev #10 | Dev #11 | Row-3 |Dev #12 | Dev #13 | Dev #14 | Dev #15 | Row-4 +--------------------------------------+ Module Locations - Rear View +--------------------------------------+ | PSU / | 2nd | 1st |OPS | PSU / | | Cooling | LRC | LRC |Panel| Cooling | | First | 'B' | 'A' | | Second | | #0 | #1 | #0 | | #1 | <--SES ID# +--------------------------------------+ Legend for Below: SN=Serial#, (optional)SC=Status Code LRC-A: SN=PMT317000005619 LRC-B: SN=PMT317000005396 Power Supply#1: SN=IMS4204300008BB Power Supply#2: SN=IMS4204300007F7 Program Ended.