Below is a  dump from a DotHill SAF-TE compliant enclosure, using SANtools smartmon-ux software. The text in RED indicates the SAF-TE components.  This was run on a Windows-based O/S, but the software is ported to Solaris, LINUX, IRIX, AIX, HP-UX, and other UNIX Variants.

smartmon-ux -I+ -E+ \\.\SCSI3:
SMARTMon-ux [Release 1.13, Build 4-SEP-2002] - Copyright 2002 SANtools, Inc. http://www.SANtools.com
Discovered CNSi JSS122 S/N " " on \\.\SCSI3: (processor) [SAF-TE] [Adapter/ID.LUN=0/0.6]
Inquiry Text Page Data - ANSI defined fields
  Device Type:                         processor
  Peripheral Qualifier:                Connected to this LUN
  Removable Device:                    NO
  ANSI Version:                        3 (SPC ANSI X3.301:1997)
  ISO/IEC Version:                     0
  ECMA Version:                        0
  Vendor Identification:               CNSi  
  Product Identification:              JSS122        
  Firmware Revision:                   L421
  Async event reporting:               NO
  Supports 16-bit wide addresses:      NO
  Supports 32-bit wide addresses:      NO
  Supports CONTINUE_TASK & TARGET XFR: NO
  Terminate task supported:            NO
  Response data format:                2
  Relative addressing supported:       NO
  Supports request/ACK data transfer:  NO
  32-bit parallel supported:           NO
  Normal ACA Supported:                NO
  Enclosure services available:        NO
  Multi-ported device:                 NO
  Medium-changer attached:             NO
  16-bit parallel supported:           YES
  Synchronous commands supported:      YES
  Linked commands supported:           NO
  Command queuing supported:           YES
 Inquiry Page Hex Dump:
  0000: 03 00 03 02 9B 00 00 32 43 4E 53 69 20 20 20 20    .......2CNSi  
  0010: 4A 53 53 31 32 32 20 20 20 20 20 20 20 20 20 20    JSS122        
  0020: 4C 34 32 31 30 20 20 20 20 20 20 20 53 41 46 2D    L4210       SAF-
  0030: 54 45 31 2E 30 30 00 00 0C 00 00 00 00 00 00 00    TE1.00..........
  0040: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00    ................
  0050: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00    ................
  0060: 43 68 61 70 74 65 63 20 42 72 69 64 67 65 20 4C    Chaptec Bridge L
  0070: 34 32 31 20 20 20 20 20 00 00 00 00 00 00 00 00    421     ........
  0080: 00 00 00 53 44 52 20 20 20 20 20 47 45 4D 32 30    ...SDR     GEM20
  0090: 30 20 20 20 20 20 20 20 20 20 20 32 20 20 20       0          2  
 Inquiry EVPD Page #00h
  0000: 7F 00 03 02 9B 00                                  ......
 SAF-TE Enclosure dump:
  Cooling/Fan #0: Operational
  Cooling/Fan #1: Operational
  Cooling/Fan #2: Not Installed (Reserved for future use)
  Power Supply #0 : Operational (Turned on)
  Power Supply #1 : Malfunctioning (Commanded on)
  Power Supply #2 : Not Installed (Reserved slot)
  Device in slot #0: Empty slot
  Device in slot #1: Empty slot
  Device in slot #2: Activated (SCSI ID is 02h)
  Device in slot #3: Activated (SCSI ID is 03h)
  Device in slot #4: Empty slot
  Device in slot #5: Activated (SCSI ID is 05h)
  Door Lock #0: Unlocked (or no controllable lock installed
  Alarm Speaker #0: Off (or not installed)
  Temperature Sensor #0: 34C / 94F
Terminating program.