Example SAF-TE Report
December 30th, 2008
Below is a dump from a DotHill SAF-TE compliant enclosure, using SANtools smartmon-ux software. The text in RED indicates the SAF-TE components. This was run on a Windows-based O/S, but the software is ported to Solaris, LINUX, IRIX, AIX, HP-UX, and other UNIX Variants.
smartmon-ux -I+ -E+ \\.\SCSI3: SMARTMon-ux [Release 1.13, Build 4-SEP-2002] - Copyright 2002 SANtools, Inc. http://www.SANtools.com Discovered CNSi JSS122 S/N " " on \\.\SCSI3: (processor) [SAF-TE] [Adapter/ID.LUN=0/0.6] Inquiry Text Page Data - ANSI defined fields Device Type: processor Peripheral Qualifier: Connected to this LUN Removable Device: NO ANSI Version: 3 (SPC ANSI X3.301:1997) ISO/IEC Version: 0 ECMA Version: 0 Vendor Identification: CNSi Product Identification: JSS122 Firmware Revision: L421 Async event reporting: NO Supports 16-bit wide addresses: NO Supports 32-bit wide addresses: NO Supports CONTINUE_TASK & TARGET XFR: NO Terminate task supported: NO Response data format: 2 Relative addressing supported: NO Supports request/ACK data transfer: NO 32-bit parallel supported: NO Normal ACA Supported: NO Enclosure services available: NO Multi-ported device: NO Medium-changer attached: NO 16-bit parallel supported: YES Synchronous commands supported: YES Linked commands supported: NO Command queuing supported: YES Inquiry Page Hex Dump: 0000: 03 00 03 02 9B 00 00 32 43 4E 53 69 20 20 20 20 .......2CNSi 0010: 4A 53 53 31 32 32 20 20 20 20 20 20 20 20 20 20 JSS122 0020: 4C 34 32 31 30 20 20 20 20 20 20 20 53 41 46 2D L4210 SAF- 0030: 54 45 31 2E 30 30 00 00 0C 00 00 00 00 00 00 00 TE1.00.......... 0040: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ 0050: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................ 0060: 43 68 61 70 74 65 63 20 42 72 69 64 67 65 20 4C Chaptec Bridge L 0070: 34 32 31 20 20 20 20 20 00 00 00 00 00 00 00 00 421 ........ 0080: 00 00 00 53 44 52 20 20 20 20 20 47 45 4D 32 30 ...SDR GEM20 0090: 30 20 20 20 20 20 20 20 20 20 20 32 20 20 20 0 2 Inquiry EVPD Page #00h 0000: 7F 00 03 02 9B 00 ...... SAF-TE Enclosure dump: Cooling/Fan #0: Operational Cooling/Fan #1: Operational Cooling/Fan #2: Not Installed (Reserved for future use) Power Supply #0 : Operational (Turned on) Power Supply #1 : Malfunctioning (Commanded on) Power Supply #2 : Not Installed (Reserved slot) Device in slot #0: Empty slot Device in slot #1: Empty slot Device in slot #2: Activated (SCSI ID is 02h) Device in slot #3: Activated (SCSI ID is 03h) Device in slot #4: Empty slot Device in slot #5: Activated (SCSI ID is 05h) Door Lock #0: Unlocked (or no controllable lock installed Alarm Speaker #0: Off (or not installed) Temperature Sensor #0: 34C / 94F Terminating program.